Panel design and manufacturing, PLC and HMI programming and on-site commissioning for companies that build their own machines.

For a company that builds its own machines, the electrical and control side is as important as the mechanics but often needs a separate specialty. Buying panel design, PLC and HMI software and on-site commissioning from outside keeps your own team focused on the machine’s mechanics and sales.

What do we do for machine builders?

Typical workflow

Work with a machine builder usually starts from the machine’s requirement list: sensors, motors, communication and operator expectations. Once the interfaces are clear, electrical drawings, panel manufacturing and PLC and HMI software proceed in parallel. The panel and software are tested at the manufacturer’s site, then the machine is installed and commissioned at the customer’s site. In series work, the design settled on the first machine is adapted to the following ones.

Typical inputs and outputs

Signal Typical example What it needs in the panel and software
Digital input Sensor, limit, button, safety contact Input card, filtering, labeling
Digital output Valve, contactor, lamp Output card, protection and sequencing
Analog input Pressure, temperature, position Signal type choice, scaling, wire-break detection
Motor and drive Conveyor, pump, servo axis Drive selection, communication, parameter backup
Communication Drive, sensor, upper system Protocol and line design
Operator interface Touch panel, button, beacon Screen design, authorization, alarms

For analog signal choice see 4-20 mA or 0-10 V?; for catching a wire break in scaling see NAMUR NE43 and PLC analog scaling.

Automation topics

  • Machine logic. Operating sequence, manual and automatic modes, fault states and a safe start position.
  • Operator screen. A simple screen that explains faults; ease of use for the customer who buys the machine carries competitive weight.
  • Alarms and diagnostics. Fault codes that are clear and in the machine’s own terms; see the alarm management guide.
  • Panel standards. The applicable standards are set by the machine and the target market; for the framework see the panel design guide.
  • Series repeat. Adapting the same panel and software to different machine sizes by changing parameters.
  • Upper-system connection. The signals to be opened up to the customer’s SCADA or data collection system are defined at the start.

Common field problems

  • A late interface. If the sensor list or motor power changes after software has started, drawings and panel are reopened.
  • A panel not tested at the factory. A panel energized for the first time on site shows its faults at the most expensive place.
  • Cable and shield layout. Not separating drive and signal cables causes noise; see the shield grounding guide.
  • Missing documents. If the person doing maintenance at the customer’s site cannot reach the drawings and I/O list, every fault takes longer.
  • Software version confusion. If different software versions across many machines are not managed, service gets harder.
  • Heat. If the heat from drives and power supplies concentrated in a small enclosure is not calculated, the panel shows intermittent faults.

What we need to quote

  • What does the machine do; how many motors, sensors and analog signals does it have?
  • What is the working environment (dust, humidity, temperature, indoor or outdoor)?
  • Is there a target market and standards or a specification your customer requires?
  • Do you prefer a certain PLC, drive and HMI; does your customer require a specific brand?
  • A single machine or series production; how many per year?
  • Which documents will you hand over (drawings, I/O list, software backup, manual)?
  • Will site commissioning be done by your team or by us?

A short description of the machine and a sensor and motor list are enough to start. Time and cost depend on the project.

How we proceed

We start with the machine’s requirement list: sensors, motors, communication and operator expectations. Once the interfaces are clear, drawings, panel and software proceed in parallel. We test the panel before shipment; for a detailed list, see our FAT checklist article. Scope, handover documents and acceptance criteria are set according to the contract.

Frequently asked questions

What should be considered when designing a machine control panel?

The machine's power and control needs, the operating environment (dust, humidity, temperature), the protection rating, maintenance access, cable and terminal layout, grounding and labeling are handled together. The standards to apply and the machine safety requirements depend on the project and the target market.

Can I outsource the PLC and HMI software?

Yes. The machine's operating logic is defined together with you; the software is prepared on the PLC and HMI side, tested and documented. At handover the source code, the I/O list and operator information are delivered together; the scope is written in the contract.

Do you build panels for series production?

Both project-based single machines and series work where the same panel is repeated are possible. In series work the panel and software are settled once and the same design is reused for later machines.

Is machine commissioning done on site or at the factory?

Usually both: the panel and software are tested first in the manufacturer's environment (FAT), then the machine is installed at the customer's site and commissioned there. Testing before going to site reduces site time and surprises.

Can I finish my own machine design and hand over only the panel and software?

Yes. You can do the mechanical design and leave the electrical, panel, PLC and HMI side to us, or you can take support on the mechanical side as well. Interfaces (sensor list, motor power, communication) are clarified at the start.

What documents are delivered with a panel?

Electrical drawings, the panel layout drawing, the bill of materials and the I/O list are usually delivered. Required documents are set in the contract and the technical specification.

My customer wants a specific PLC brand. Can you accommodate that?

Send the list of brands and models you want and, if there is one, your customer's specification, and we will check the fit together. The brand choice is made per project.

I ship my machine abroad. Can the panel be prepared for that?

If the target country's supply voltage, the applicable standards and your customer's specification are clarified at the start, the panel is designed accordingly. The choice of standard depends on the target market and the contract; we clarify it together at the start of the project.

Send us the problem. We reply within one business day.

A drawing, a P&ID, a photo or two lines of description is enough.