Glossary
Short definitions of the automation terms used in our notes and service pages. Where a note explains a term in detail, it is linked next to the term.
- PLC (programmable logic controller)
- Industrial controller that reads field inputs and runs the control logic.
- HMI (human-machine interface)
- The local screen through which an operator monitors and operates a machine or process.
- SCADA
- Supervisory layer that gathers many points for monitoring, alarms and records.
- Historian
- Component that stores time-stamped process data for trends and reports.
- RTU (remote terminal unit)
- Remote device that collects signals at a site and relays them to the center.
- I/O list
- List of all input/output signals with type, address and description.
- Tag
- The name given to a single measurement or state value in SCADA.
- P&ID
- Process diagram showing piping, equipment and instruments.
- FAT (factory acceptance test)
- Acceptance test performed at the supplier before shipment.
- SAT (site acceptance test)
- Acceptance test performed on site after installation.
- 4-20 mA
- Current-loop analog signal; 4 mA is the low end, 20 mA the high end.
- NAMUR NE43
- Recommendation defining signal ranges used to flag faults (e.g., wire break) on 4-20 mA. Confirm range values in the note and the standard.
- Scaling
- Converting a raw PLC count to an engineering unit.
- Modbus RTU
- Serial communication protocol commonly run over RS-485.
- RS-485
- Multi-drop balanced serial line standard.
- Termination
- Resistor at line ends that reduces reflections.
- Bias
- Line polarization giving a defined level when the bus is idle.
- OPC UA
- Vendor-neutral industrial data-exchange protocol.
- Hysteresis
- Gap between on and off thresholds that prevents rapid cycling.
- Deadband
- Band within which small changes are not recorded.
- Punch list
- List of open items remaining after acceptance.
- As-built
- Documents updated to match what was actually installed.
- Shield grounding
- How and where a cable shield is grounded; it affects noise.
- ISA-18.2
- Alarm-management lifecycle standard. Confirm clause details from the source.
- ISA-101
- Standard on operator screen (HMI) design for process automation systems. Confirm clause details from the source.
- Alarm flood
- A large number of alarms arriving in a short time, making it hard for the operator to tell the important one.
- Trend
- A graph showing how a value changes over time.
- Setpoint
- The target value the control system tries to reach and hold for a measured variable.
- PID
- Control algorithm that produces an output from proportional, integral and derivative actions to hold a measured value at its target.
- Interlock
- Logic that allows a piece of equipment to run only when certain conditions are met.
- Recipe
- A product's parameter set (amounts, order, time, temperature and so on); applied automatically by the PLC when selected.
- Variable frequency drive (VFD)
- Electronic drive that adjusts motor speed by changing the supply frequency.
- Profinet
- Ethernet-based industrial communication protocol.
- Modbus TCP
- The version of Modbus that runs over Ethernet.
- BACnet
- Communication protocol used in building automation.
- Register map
- The address table of a device's readable and writable values; taken from the device documentation before communication is set up.
- Gateway (protocol converter)
- A device that translates the data of one protocol into another; connects devices with different interfaces to one system.
- VPN
- A connection that sets up an encrypted tunnel between two networks or devices over the internet; used for remote access.
- DMZ (demilitarized zone)
- A separate network zone between the control (OT) network and the office (IT) network, set up for passing data.
- Network segmentation
- Splitting a network into zones and limiting traffic between them with rules; makes it harder for a problem in one zone to spread to another.
- CIP (clean in place)
- Automatic washing of tanks and pipes on food and beverage lines without dismantling them.
- Dry running
- A pump running with no liquid inside; risks overheating and damage, and is guarded by level or current information.
- IP rating
- Code showing an enclosure's protection against dust and water.
- Skid
- A unit in which equipment such as a pump, filter or dosing system is assembled on a single frame.
- PFD
- Process flow diagram showing the main steps and flows of a process in a simple form.
- Quantity take-off
- Measuring a job's quantity items from the project and the site and putting them in a schedule.
- Progress payment
- A contractor's payment claim for work done; checked by comparing it with quantities measured on site.
- FEA and CFD
- FEA calculates a structure's stress and deformation under load; CFD calculates fluid flow numerically.
- GD&T
- Geometric dimensioning and tolerancing, a way of defining part geometry and tolerance with standard symbols.
Send us the problem. We reply within one business day.
A drawing, a P&ID, a photo or two lines of description is enough.